Fire Door Labeling

Fire Rated Frame and Door Labels

By |2020-03-31T16:37:07+00:00March 31st, 2020|Fire Door Inspection, Fire Door Labeling|

Fire rated frames and doors labels are used to prevent the passage of fire and smoke between two compartments. Fire rated frames and doors labels  are used as a passive means of protecting people and property from fires. Model codes in the United States generally reference NFPA 80 : Standard for Fire doors and Others

Top 10 Fire Door Deficiencies (And Fire Rated Door Labels)

By |2020-02-26T16:54:48+00:00December 18th, 2019|Fire Door Inspection, Fire Door Labeling, News|

1. Painted or missing fire door labels The fire rated door labels found on the edge or top of a fire door and frame may be made of metal, paper, or plastic, or may be stamped or die-cast into the door or frame. Labels must be visible and legible. Some embossed labels can still be

Highrise Buildings Fire Door Safety

By |2020-02-24T19:17:13+00:00December 18th, 2019|Fire Door Inspection, Fire Door Labeling, News|

High-rise Buildings Fire Door Safety High-rise buildings fire door safety is one of our main services. We pass through these doors every day in high-rise buildings, commercial, institutional, and residential buildings. A lack of awareness can lead to modifications or deficiencies which affect the opening protective’s performance when it’s critical – during a fire. Many

Fire Inspection Companies

By |2020-02-24T19:40:51+00:00December 18th, 2019|Fire Door Inspection, Fire Door Labeling, News|

Fire Inspection Companies – Sarasota We are rated among the top fire inspection companies in Florida. Fire doors and smoke doors create a seal that provides protection from the effects of flames and smoke during a fire. Smoke doors block smoke and other combustible products, while fire doors stop flames by compartmentalizing. A fire door

Certified Fire Door Inspector Ready to Certify Your Fire Doors

By |2020-02-24T19:42:57+00:00December 18th, 2019|Fire Door Inspection, Fire Door Labeling, News|

Certified Fire Door Inspector Ready to Certify Your Fire Doors Who has the license to enforce NFPA 80? The Authority Having Jurisdiction, (AHJ) has the authority to enforce NFPA 80. The AHJ comprises of Fire Marshals, The Joint Commission, (TJC) and CMS. You must be a certified fire door inspector to approve the safety of

Fire Door Service

By |2020-02-24T19:44:32+00:00December 18th, 2019|Fire Door Inspection, Fire Door Labeling, News|

Fire Door Service Fire door service for healthcare facilities. Are your fire doors compliant and documented? The Centers for Medicare & Medicaid Services (CMS) adoption of the 2012 edition of NFPA 101: Life Safety Code requires that healthcare facility operators conduct a yearly inspection of fire door and smoke barrier door alike in accordance with

Fire Door Maintenance

By |2020-02-24T19:46:21+00:00December 18th, 2019|Fire Door Inspection, Fire Door Labeling, News|

Fire Door Maintenance Fire door maintenance is very important. A fire door is not just the door leaf. It is a complete assembly comprising the frame, any glazing, intumescent fire and smoke seals and all the ironmongery that is used on the door, such as hinges, overhead door closers, latches and locks. Just like other

Fire Door Inspection & Label in Florida

By |2020-02-24T19:48:12+00:00November 22nd, 2019|Fire Door Inspection, Fire Door Labeling, News|

Fire Door Inspection & Label in Florida Florida Fire Door Inspection & Label serve all the State of Florida. We are professional and expert fire door inspection and labeling. We are certified by Door Hardware Institute as Fire and Egress Door Assembly Inspector, Intertek Qualified Personal to perform fire door inspection,  certified by the National

Relabel Fire Door in Florida

By |2020-02-24T19:49:48+00:00November 21st, 2019|Fire Door Inspection, Fire Door Labeling, News|

We Re-Label Fire Door The most top reason for non-compliant fire rated assembly (doors and frames) are painted, damaged, or missing fire re-label fire door frames to make sure it is complaint with laws. NFPA 80 requires that all fire door openings (both doors and frames) are required to have a fire rated certification label

Fire Door Inspection Companies in Florida

By |2020-02-24T19:50:36+00:00November 20th, 2019|Fire Door Inspection, Fire Door Labeling, News|

Fire Door Inspection Companies in Florida Fire doors are designed to protect the structural stability of a building long enough for firefighters to extinguish the flames. Fire door assemblies are designed to provide time for occupants to escape a burning building. Few people fully understand the forces and stresses fire door assemblies are subjected to